dc.description | Este estudo, ex vivo, teve por objetivos comparar a medição eletrônica (ME) com a medida real do dente e avaliar a influência do diâmetro apical e do calibre do instrumento na determinação do comprimento do dente pelo localizador eletrônico (LE) NOVAPEX. Foram utilizados vinte dentes unirradiculares e um aparato com alginato/soro fisiológico. A medida real do dente foi determinada pela visualização apical de uma lima tipo Kerr (LK) #10 (Grupo A). As ME foram divididas em sete grupos: Grupo B (ME utilizando LK #15); Grupo C (ME utilizando LK #15) e Grupo C1 (ME utilizando LK #50), ambos após ampliação foraminal em 0,50 mm; Grupo D (ME utilizando LK #15) e Grupo D1 (ME utilizando LK #60), ambos após ampliação foraminal em 0,60 mm; Grupo E (ME utilizando LK #15) e Grupo E1 (ME utilizando LK #80), ambos após ampliação foraminal em 0,80 mm. Os grupos foram comparados por meio do teste t de Student pareado. Os resultados não revelaram diferença estatisticamente significativa (p > 0,05) entre os Grupos A e B, considerando-se uma tolerância de 0,5 mm entre essas medidas, e entre o Grupo B e os Grupos C, C1, D e D1. Porém, entre o grupo B e os grupos E e E1 houve diferença estatisticamente significante (p < 0,05). Concluiu-se que a ME com LE NOVAPEX equivale a medida real do dente, e que a determinação do comprimento do dente sofre influência do diâmetro apical, entretanto, o calibre do instrumento não influencia a ME. | pt_BR |
dc.description.abstract | The aim of this ex vivo study was to compare the electronic measure (EM) with the real measure of the tooth and to evaluate the influence of the apical diameter and the instrument caliber in determining the length of the tooth by the electronic locator (EL) NOVAPEX. Twenty single root teeth and an apparatus with alginate/ physiological sodium chloride have been used. The real measure of the teeth was determined by the apical visualization of a Kerr file (LK) #10 (Group A). The EM has been divided in seven groups: Group B (EM using LK #15); Group C (EM using LK #15) and Group C1 (EM using LK #50), both after the foraminal enlargement until 0,50mm; Group D (EM using LK#15) and Group D1 (EM using LK #60), both after the foraminal enlargement until 0,60mm; Group E (EM using LK #15) and Group E1 (EM using LK #80), both after the foraminal enlargement until 0,80mm. The groups have been compared by the Student paired t test. The results do not reveal significant statistically differences (p > 0,05) between the Groups A and B, considering a tolerance of 0,5mm between those measures, as well as between the Group B and the Groups C, C1, D and D1. Nevertheless, comparing the Group B with the Groups E and E1 there was a significant difference (p < 0,05). It was concluded that the EM with the EL Novapex is equal to the real measure and that the determination of the tooth length is influenced by the apical diameter, however, the instrument caliber does not influence the ME. | en_US |
dc.language.iso | por | pt_BR |
dc.publisher | Revista Naval de Odontologia | pt_BR |
dc.rights | openAccess | pt_BR |
dc.subject | Odontologia | pt_BR |
dc.subject | Saúde | pt_BR |
dc.subject | Endodontia | pt_BR |
dc.subject | Odontometria | pt_BR |
dc.subject | Tratamento do canal radicular | pt_BR |
dc.title | A influência do diâmetro apical na eficácia do localizador eletrônico Novapex: estudo ex-vivo | pt_BR |
dc.title.alternative | The influence of apical diameter in the effectiveness of electronic apex locator Novapex: ex-vivo study | en_US |
dc.type | journalArticle | pt_BR |
Aparece nas coleções: | Saúde: Coleção de Artigos |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
00001c6b.pdf | 499,27 kB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.