Use este identificador para citar ou linkar para este item:
https://www.repositorio.mar.mil.br/handle/ripcmb/844206
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor | Abreu, Mariana Mota | - |
dc.contributor | Ferreira, Reinaldo de Souza | - |
dc.contributor | Mota, Cristiane Soares | - |
dc.contributor.author | Abreu, Mariana Mota | - |
dc.contributor.author | Ferreira, Reinaldo de Souza | - |
dc.contributor.author | Mota, Cristiane Soares | - |
dc.date.accessioned | 2019-09-10T16:41:10Z | - |
dc.date.available | 2019-09-10T16:41:10Z | - |
dc.date.issued | 2014 | - |
dc.identifier.uri | http://www.redebim.dphdm.mar.mil.br/vinculos/00001c/00001ccb.pdf | - |
dc.identifier.uri | http://www.repositorio.mar.mil.br/handle/ripcmb/844206 | - |
dc.description | O presente estudo teve como objetivo avaliar a influência do clareamento dental sobre a sorção salivar de uma resina de baixa contração baseada em silorano (Filtek TM P90, 3M ESPE), quando comparada a uma resina baseada em dimetacrilatos ( Filtek TM Z250, 3M ESPE). Dez corpos de prova (CP) de cada resina composta foram confeccionados apartir de uam matriz metálica bipartida ( 5mm x 1mm). Os CP foram fotoativados com unidade LED (1.400mW/cm²). Todos os CP forma imersos em saliva artificial por 1 mês e metade deles doi submetida semanalmente a protocolo de tratamento clareador (TC) de consultório com gel de peróxido de hidrogênio 35% (Whitegold, Dentsply Brasil). Dessa forma, foram formados 4 grupos (n=5): (G1) Z250, sem TC; (G2) Z250 com TC; (G3) P90 sem TC; e (G4) P90 com TC. Avaliação da sorção foi realizada através de pesagens em balança analítica de precisão, de acordo com a ISO 4049/2000. Os dados foram analisados pleos estes ANOVA2- fatores e de comprações múltiplas Student Newman Keuls (p=0,05). A ordem dos valores de sorção foi: G2>G4>G1>G3, sem diferença estatística entre eles. Os fatores compósito (p=0,2117) e meio (p=0,1584) não exerceram influência significativa sobre os valores de sorção. Conclui-se que o clareamento dental não afetou os valores de sorção dos compósitos avaliados e não houve diferença de comportamento entre os diferentes compoósitos em ambos os meios testados. | pt_BR |
dc.description.abstract | The aim of the present study was to evaluate the influence of dental bleaching on the salivary sorption of a low shrinkage dental composite based on silorane monomer (FiltekTM P90, 3M ESPE, EUA) in relation to a methacrylate-based composite (FiltekTM Z250, 3M ESPE, EUA). Ten specimens of each material were fabricated in sectioned customized metaçlic mold ( 5mm x h 1mm). The composites were photo activated with a LED unit (1.400mW/cm²). All specimens were immersed in artificial saliva for 1 month and half of them was weekly submitted to an in -office bleaching protocol (BP) with 35% hydrogen peroxide (Whitegold, Dentsply Brasil). So, four groups (n=5) were analyzed: (G1) Z250 with BP; (G2) Z250 with BP; (G3) P90 no BP; and G(4) P90 with BP. the measurements of sorption behavior were made by weighing in anaaytical balance, according to ISO 4049/2000. Data were analyzed by 2-factor ANOVA and Student-Newman -Keuls post-hoc test (p=0.05). The sorption behavior was: G2> G4> G1> G3, and medium (p = 0.1584) did not show significant influence on the sorption's values. It was concluded that the bleaching treatment did not affect the values of sorption of the composites evaluated ande there was no difference in sorption behavior between different composites in both media tested. | en_US |
dc.language.iso | por | pt_BR |
dc.publisher | Revista Naval de Odontologia | pt_BR |
dc.rights | openAccess | pt_BR |
dc.subject | Odontologia | pt_BR |
dc.subject | Saúde | pt_BR |
dc.subject | Dentes de Dentes | pt_BR |
dc.subject | Saliva artificial | pt_BR |
dc.subject | Resinas Compostas | pt_BR |
dc.title | Efeito do clareamento do consultório sobre a sorção de um compósito de baixa contração | pt_BR |
dc.type | journalArticle | pt_BR |
Aparece nas coleções: | Saúde: Coleção de Artigos |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
00001ccb.pdf | 4,36 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.